Paxton Net2 I/O board Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Für Zuhause Paxton Net2 I/O board herunter. Paxton Net2 I/O board User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 7
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Ins-30019 Net2 I/O board
20/08/2012
Output 1
12V DC
Power Inputs
Reader 2Reader 1
Red
Brown
Orange
Green
Yellow
Blue
Mauve
Black
Red
Brown
Orange
Green
Yellow
Blue
Mauve
Black
Relay 1 Relay 2 Relay 3 Relay 4
Input 1
Input 2
Input 3
Input 4
Output 2
Output 3
Output 4
Input terminal (FOR FUTURE USE)
Patch lead
Diagnostic LED's
Net2 I/O Boards are congured to switch their relays by setting up a 'Triggers and Actions' rules.
Four inputs are provided to allow connection to door contacts, etc, without the need of a Net2 ACU.
Four output relays are also provided to switch a variety of AC and DC output devices. The relay
contacts are rated at 13A at 240V AC, to enable mains voltages to be switched.
Technical Support
Technical help is available: Monday - Friday from 07:00 - 19:00 (GMT)
Saturday from 09:00 - 13:00 (GMT)
01273 811011
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/
The I/O board is a Network based product and requires connection to the PC via a TCP/IP connection.
This unit requires the controlling PC to be running Net2 v4 software.
- 3V Power LED
- 5V Power LED
- OK LED - This should ash regularly
- 100 M - On = 100 Mbit/s : Off = 10 Mbit/s
- Link - The I/O board is connected to a Network port
- Data - The I/O board is receiving ethernet data
Diagnostic LED's
Paxton
Seitenansicht 0
1 2 3 4 5 6 7

Inhaltsverzeichnis

Seite 1 - 01273 811011

Ins-30019 Net2 I/O board20/08/2012Output 112V DC Power Inputs Reader 2Reader 1RedBrownOrangeGreenYellowBlueMauveBlackRedBrownOrangeGreenYellowBlueMauv

Seite 2 - Detection of the I/O boards

Select 'I/O boards' in the left hand tree diagram.To enable the 'I/O board' icon, the 'Triggers & Actions' icon need

Seite 3

I/O boards that have been detected will be displayed with their MAC address.Double click on an entry and it will bring up its conguration screen. Th

Seite 4 - Firmware download

If the I/O board is connected to a dierent IP range to the PC, it will not be detected. You must therefore make a manual entry in the I/O table so t

Seite 5 - Inputs and Outputs

Inputs and Outputs Simply double click on an entry to rename the item and click Apply. These names will be used in any 'Triggers and Actions&apos

Seite 6 - Triggers and Actions

The basic control of an I/O board is provided by 'Triggers and Actions'.An air conditioner can be turned on remotely by the presentation of

Seite 7 - Safety Requirements

Only qualied Engineers should install and service this equipment.Read the instructions before installing and powering the equipment. Adhere to all in

Kommentare zu diesen Handbüchern

Keine Kommentare